Foam Proportioner Robwen Flowmix

The DOUBLE kit version is used to double the reserve of foam concentrate to transport or diversify the reserve of foam concentrate to transport in order to proportion two different types of concentrate. 3 versions are available to suit all needs. The ROBWEN FLOWMIX is a storage and dosing unit specially designed for Class A additives.

  • Wide flow rate range
    ROBWEN FLOWMIX can be used from 5 gpm to 500 gpm (for a concentration of 0.1 to 1%) and up to 125 gpm (at 3%).
  • Wide dosage range
    Precise dosage: 0.1%, 0.2%, 0.3%, 0.4%, 0.5%, 0.7%, 1% and 3%.
  • Autonomous
    Entirely based on the mechanical principle of a Storage and Dosing Unit, FLOWMIX does not require any auxiliary energy source and operates automatically downstream of the pump.
  • Low-pressure loss
    Perfect for laying long pipe lengths, FLOWMIX can be used from 20 psi up to 435 psi.

Features

  • Foam Proportioner-Vehicle Robwen Flowmix - double kit version LEADER
  • Foam Proportioner Robwen Flowmix - double kit version LEADER
  • Foam Proportioner-Trucks Robwen Flowmix - double kit version LEADER

product characteristics

ROBWEN FLOWMIX was specially designed for fire fighting, and its integrated reserve of foam concentrate stores the foam concentrate under ideal conditions protected from UV rays and oxygen.
Easy to use, simply connect it to a water supply so that it can accurately measure the additive to be injected.
Its range of flow rates and concentration – 5 gpm to 500 gpm (for a concentration of 0.1 to 1%) and up to 125 gpm (at 3%).- makes it very versatile. Generating only very low-pressure losses, ROBWEN FLOWMIX is ideal for long-length installations like in, for example, forest fire response.

Data Sheet

GENERAL CHARACTERISTICS

FLOW RATE 5 to 500 gpm (max 125 gpm if 3%)
OPERATING PRESSURE 20 to 435 psi
DOSAGE 0.1% , 0.2% , 0.3%, 0.4%, 0.5%, 0.7%, 1% and 3%
INLET / OUTLET 2.5’’ BSP male
STORAGE TEMPERATURE -32°F to +140°F
OPERATING TEMPERATURE 32°F to +120°F
PRESSURE LOSS only 20 psi at 264 gpm
BYPASS TO REDUCE PRESSURE LOSSES No
INLET PRESSURE GAUGE No
WEIGHT (WITHOUT EXTRACTION TUBE) contact us
DIMENSIONS W X D X P contact us
CARRYING CASE Yes for the portable version

Downloads

Cutsheet PDF Product Manual PDF